• Other Seaward Sites:

SafeCheck 8 Electrical Safety PAT Tester

SafeCheck 8 Electrical Safety PAT Tester

Limited Offer, now only £1200 + VAT and Carriage

Hire & Rental Industry Tester that Stores Results and Prints Tested Labels

The new SafeCheck 8 tester has been designed specifically to ensure that traceable test results can be stored for rental products when PAT tested between hires.  These traceable test results will clearly demonstrate that a rental product supplied into the DIY or construction industry is electrically safe and functions correctly, at the time of hire.  This is a basic requirement of the HSE, specifically under the Electricity at Work regulation which stipulates that the supplier must re-test the product to the same standard used at the time of manufacture (CE).  The tests that must therefore be applied are earth/ground bond, flash/hipot, and function test to check correct operation this which may include current consumption, continuity, polarity and leakage measurements. 

Please note that the majority of in-service PAT testers cannot meet these test requirements, as they have their test output limited to less than 2.5 mA for leakage delivered under the flash/hipot test.  A large proportion of in-service PAT testers do not offer this mandatory flash/hipot test. 

The SafeCheck 8 tester has been ergonomically designed for rugged bench use within service and repair centres.  It features a large high contrast LCD display and the user interface is clear and simple, with test sequences pre-configured for Class I grounded, Class II double insulated, and extension lead/power cord product types.  Additional test sequences can also be programmed into the tester either from the menu or simply from a series of barcodes that can be held within a work instruction document issued to the operator or service centre. In addition to full test result traceability, including user and location, the SafeCheck 8 has been designed to greatly simplify the testing process, and automate items such as asset tracking and the printing process of tested pass/fail labels, which can then be attached to the power cord of the power tool or appliance under test. Not only can the SafeCheck 8 read power tool appliance asset or serial numbers via a barcode scanner, but it can transfer this information onto an indelible tested pass/fail label, via a Desk Test n Tag Printer.  Appliance or asset numbers may then be tracked through Pat Guard, our MS Windows application that is available as an accessory.
 
For outstanding value for money and to help you meet your safety obligations whilst improving productivity, why not contact us for a product demonstration of the new SafeCheck 8!
 

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

 

  • The only dedicated Hire and Rental Industry specific tester
  • Stores up to 6000 test results in flash secure memory
  • Has built in pre-configured tests for Class I, Class II and extension lead/power cord 
  • Can be automated with a barcode scanner to enter user, location, asset/SN, and other text fields
  • Test sequences can be entered from barcodes
  • Earth/Ground Bond test
  • Flash/hipot dielectric withstand test
  • DC Insulation test
  • Full function run test
  • Leakage test
  • Continuity and polarity test
  • Visual inspection test field included
  • Can be used with Desk Test n Tag indelible pass/fail label printer
  • Flash memory stores results without mains supply
  • Unit is supplied with power cord, test probes and instruction booklet

Downloads

Please feel free to download any of the documents associated with this product.

Technical Specification

Earth/Ground Screen Test (IT Earth/Ground Bond Test)

Test Voltage 100mV nominal (no load)

Test Current 100mA (into s/c load)

Range 40mΩ - 19.99Ω

Resolution 1mΩ

Accuracy +/- 5% +/- 2 digits

Pass Levels user selectable

DC Insulation Test

Test Voltage 500V

Display Range 0.1 - 99.99MΩ

Accuracy +/- 5% +/- 2 digits (up to 19.99MΩ)

Short to Case Test

Test Voltage 40V a.c. o/c

Display Range 0.1 - 20.0 mA a.c.

Resolution 0.01mA

Accuracy +/- 10% +/- 2 digits (1.00 - 20mA)

Pass Levels selectable up to 15mA

Flash/Hipot Test (CLASS 1)

Test Voltage 1.25kV a.c

Display Range 0.1 - 10 mA a.c.

Resolution 0.01mA

Accuracy +/- 5% +/- 2 digits

Pass Levels selectable up to 10mA

Flash/HipotTest (CLASS II)

Test Voltage 2.5 kV a.c

Display Range 0.1 - 10 mA a.c.

Resolution 0.01mA

Accuracy +/- 5% +/-

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.

Product Enquiry

Contact Information

indicates required field
Title*
Please type in the validation code from the image (case sensitive).

Additional Information (optional)

 
Site engineered by NorthBloc   
© 2008, Seaward Electronic Group Ltd. All rights reserved.